Contents

Results and failures

A check ends passed, failed or not tested; a drill ends as passed these checks, failed or cancelled. This page says how DownDrill decides, and what each cause of a failure means and what to do about it.

Three results

Each check ends with one of three results:

passed
It ran and found what it expected.
failed
It ran and found something else, crashed, or was required and could not run.
not tested
It did not run, and the evidence says why: it is optional and could not run, a required check before or during the restore failed first, or the drill cannot exercise it. Nothing is claimed about it.

A drill ends in one of three ways:

Passed these checks
At least one check passed, none failed and every required check passed. It speaks for the checks listed, on the date shown.
Failed
Any other drill that finished, with one of the nine causes below.
Cancelled
An administrator pressed Cancel queued drill before a runner took it. Nothing was tested, and there is no evidence or ledger entry.

An optional check that runs and finds a problem fails the drill like a required one. Checks lists when each check is not tested.

Who decides

The runner reports each check and its own verdict. The control plane, the part of DownDrill you sign in to, works the result out again from the checks:

The evidence, the ledger, the emails and recovery debt all use that result.

Every failure cause

A failed drill has one cause. The evidence page, its PDF and the failure email give its title, the detail, a likely cause and a next step; the evidence JSON, the ledger entry and the monthly evidence pack give its name. After a fix, anyone in your organisation can press Run a drill now on the asset’s page.

missing_archive

The backup was not found at its source. There was no backup under the bucket’s prefix, no such bucket or object, no complete WordPress set, no container of the named Compose project on the runner’s Docker host, or no held copy in the vault. The detail says which.

Likely reasons: the backup job did not run, or it writes somewhere else now.

What to do: check the job. An administrator can correct the source with Reconnect the backup source in Asset settings.

wrong_credentials

Could not connect or sign in to the source. A password or key was refused or has expired, the user, role or database named does not exist, or the host could not be found or reached. It is also the cause when a host resolves to an address that is not public, and when a database login is not read-only: a PostgreSQL superuser or a role that can write to a table, or a MySQL or MariaDB user with anything beyond SELECT and SHOW VIEW, or without both granted directly on the whole database.

Likely reasons: rotated credentials, or a source that does not let the runner in.

What to do: an administrator updates the source with Reconnect the backup source in Asset settings; saving it runs the connection test again. For a login that is not read-only, the detail gives the statements for one that is.

corrupt_dump

The backup did not restore cleanly. A dump or archive is empty, damaged or cut short, or the restore stopped on an error no other cause names. It also covers a held copy that no longer matches its recorded SHA-256, an archive entry that is a link or points outside its folder, a PostgreSQL restore that left objects unrestored on such an error, and a database WordPress does not recognise, cannot upgrade or cannot move to the drill’s address.

Likely reasons: an interrupted backup or upload.

What to do: take a fresh backup and run the drill again; until one passes, treat this backup as unusable. Test this copy shows whether an older copy restores.

plugin_lock

A plugin or maintenance lock blocked the restored site. A WordPress drill records it when the homepage or wp-login.php showed “Briefly unavailable for scheduled maintenance”, when wp-login.php answered 401, 403, 404 or 503 while the homepage check did not fail, or when the test administrator’s sign-in was refused while neither page’s check failed. The detail lists up to 20 of the site’s active plugins.

Likely reasons: a security, login or maintenance plugin, or a site backed up in maintenance mode.

What to do: find the plugin among those listed. If it must stay, give the drill a way to reach the login page.

timeout

The drill ran out of time. It reached its time limit, or a step reached its own, such as an import, the smoke tests or a server that was not ready in time. It is also the cause when a runner stops renewing its lease, and when a drill waits too long in the queue with no runner checking in.

Likely reasons: the backup has outgrown the time limit, or the source or the runner stopped responding.

What to do: a first attempt is retried once. If the retry fails and the detail says the drill ran out of time, an administrator can raise Maximum drill time in Asset settings.

smoke_test_failure

The restore finished but a check failed. A page did not answer as expected, tables or rows are missing, a sample query gave another answer or a recovery target was missed, for example. It is also the cause when every step ran but a required check could not, or no check passed.

Likely reasons: what came back differs from what the checks expect: the backup lacks something, or a check expects what has since changed, such as a schema version.

What to do: the evidence page shows what each check found. If a check is out of date, an administrator can change it in Asset settings.

unsupported_format

This backup format or version is not supported. The detail names what DownDrill cannot restore yet, such as an encrypted or incremental UpdraftPlus set, WordPress multisite, MySQL 9, a PostgreSQL extension with no restore image or a Compose service with a host mount. An image that cannot be pulled fails the same way.

Likely reasons: the backup is made in a way DownDrill does not restore yet or, for a Compose application, an image name or the registry login is wrong.

What to do: compare the backup with What it restores. Until a drill passes, the asset has not been shown to restore.

resource_limit

The drill hit a resource limit. The backup is larger than the limit for a copy or unpacks to more than its limit, an archive holds too many files, a container ran out of memory, or the drill ran out of disk space. The detail says which.

Likely reasons: the backup, or the system restored from it, needs more than the drill allows.

What to do: make the backup smaller where you can. These limits are not settings in the app; the evidence JSON records the memory, CPU, process and time limits the drill ran with.

runner_error

The drill runner failed. The runner crashed, could not start a container or store the copy, or reported a pass its checks do not support, so nothing was shown either way. An error from your storage, or from a live dump or capture, that matches no other cause is recorded here too.

Likely reasons: a fault on DownDrill’s side, unless the detail points at your storage or database.